TM 9--2350--292--20--10018 00--11AUXILIARY POWER UNIT FAILS TO CRANK -- CONTINUED0018 00CONTINUED FROM STEP QIs glow plug warm or hot?ZnoyesCONTINUED FROM STEP YDoes relay click?noyesAAReplace glow plug (WP 0629 00). Verifyfault is corrected.1. Turn PREHEAT switch to MOM ON(TM 9--2350--292--10).2. Place hand close to, but not directly on,glow plug.3. Feel for glow plug heating up.1. Reconnect harness 4W700 P1 to APUcontrol box, if disconnected.2. Reconnect harness 4W702 P2 to bulkheaddisconnect, if disconnected.3. Turn MASTER switch ON(TM 9--2350--292--10).4. Turn PREHEAT switch to MOM ON(TM 9--2350--292--10).5. Turn START switch to MOM ON(TM 9--2350--292--10), turn START switchON and OFF several times.6. Listen for starter relay to click.7. Turn MASTER switch OFF.Go to Step AG.CONTINUED ON NEXT PAGE