TM 9--2350--292--20--10018 00--16AUXILIARY POWER UNIT FAILS TO CRANK -- CONTINUED0018 00CONTINUED FROM STEP AInoyesAJRepair (WP 0290 00) orreplace (WP 0332 00)harness 4W700. Verifyfault is corrected.noyesAKRepair (WP 0290 00) orreplace (WP 0247 00)harness 4W725. Verifyfault is corrected.Is continuity present?CONTINUED ON NEXT PAGEIs continuity present?1. Disconnect harness 4W700 P1 from APUcontrol box connector 4W725.2. Place multimeter red lead to harness 4W700P1 socket B and black lead to harness4W700 P2 bulkhead receptacle pin A.3. Check for continuity.1. Disconnect harness 4W725 lead 65connector from circuit breaker CB1connector.2. Place multimeter red lead to harness 4W725pin B and black lead to lead 65 connector.3. Check for continuity.