TM 9--2350--292--20--10018 00--17AUXILIARY POWER UNIT FAILS TO CRANK -- CONTINUED0018 00CONTINUED FROM STEP AKnoyesALReplace circuit breakerCB1 (WP 0247 00).Verify fault is corrected.noyesAMReplace lead 4W123--5(WP 0247 00). Verifyfault is corrected.Is continuity present?CONTINUED ON NEXT PAGEIs continuity present?1. Disconnect 4W123--5 lead 65A from circuitbreaker CB1 connector.2. Place multimeter leads across circuitbreaker CB1 connectors.3. Check for continuity.1. Reconnect harness 4W725 lead 65 to circuitbreaker CB1 connector.2. Disconnect 4W123--5 lead 65A from STARTswitch S1.3. Place multimeter leads across 4W123--5lead 65A.4. Check for continuity.