TM 9--2350--292--20--10018 00--13AUXILIARY POWER UNIT FAILS TO CRANK -- CONTINUED0018 00noyesADReplace starter relay(WP 0641 00). Verifyfault is corrected.AECONTINUED FROM STEP ACnoyesRepair (WP 0290 00) orreplace (WP 0651 00)lead 3W727. Verify faultis corrected.CONTINUED ON NEXT PAGE1. Disconnect lead 3W727 from starter relayterminal X2.2. Place multimeter red lead to starter relayterminal X2 and black lead to ground.3. Turn MASTER switch ON(TM 9--2350--292--10).4. Turn PREHEAT switch to MOM ON(TM 9--2350--292--10).5. Turn START switch to MOM ON(TM 9--2350--292--10).6. Check for voltage.7. Turn MASTER switch OFF.Is 24 V dc present?1. Place multimeter leads on lead 3W727 andcommon ground E3.2. Check for continuity.Is continuity present?