TM 9--2350--292--20--10076 00--2EXHAUST SMOKE INDICATOR LIGHTS FAIL TO OPERATE -- CONTINUED0076 00CONTINUED FROM STEP BC1. Disconnect lead 10 from CB6.2. Place one multimeter lead on harness 4W151J4 pin N and other lead in lead 10 CB6connector socket. Check for continuity.Is continuity present?yes noRepair (WP 0290 00) orreplace (WP 0242 00)lead 10 to CB6. Verifyfault is corrected.noyesReplace CB6 (WP 0242 00).Verify fault is corrected.DE1. Disconnect lead 25/27 from CB6.2. Place one multimeter lead on each CB6connector pin. Check for continuity.Is continuity present?Is continuity present?noyes1. Reconnect lead 10 to CB6.2. Place one multimeter lead in lead 25/27 CB6connector socket and other lead in harness4W151 J4 pin K. Check for continuity.Repair (WP 0290 00) orreplace (WP 0242 00)lead 25/27. Verify faultis corrected.CONTINUED ON NEXT PAGE