TM 9--2350--292--20--1
0076 00--4
EXHAUST SMOKE INDICATOR LIGHTS FAIL TO OPERATE -- CONTINUED
0076 00
CONTINUED FROM
STEP G
CONTINUED FROM STEP H
CONTINUED ON NEXT PAGE
I
Is continuity present?
no
yes
Replace drivers
EXHAUST SMOKE
switch (WP 0259 00).
Verify fault is corrected.
J
1. Reconnect lead 27A to switch S10.
2. Place one multimeter lead on lead T1
connector pin and other lead in harness 4W118
J1 socket A. Check for continuity.
Is continuity present?
no
yes
Repair (WP 0290 00) or
replace (WP 0242 00)
lead T1 to switch S10.
Verify fault is corrected.
1. Disconnect lead T1 from switch S10 connector.
2. Place one multimeter lead on switch S10
connector socket for leads 27A and T1. Check
for continuity.
K 1. Reconnect lead T1 to switch S10.
2. Disconnect lead T2 from indicator L3.
3. Place one multimeter lead in lead T2 L3
connector socket and other lead in harness
4W118 J1 socket A. Check for continuity.
Is continuity present?
no
yes
Repair (WP 0290 00) or
replace (WP 0242 00)
lead T2 to indicator L3
connector. Verify fault is
corrected.