TM 9--2350--292--20--10098 00--5BOOM CREEPS WITH BOOM CONTROL IN NEUTRAL -- CONTINUED0098 00Notify Direct SupportMaintenance.CONTINUED FROM STEP EIIs pressure reading 1500--1900 psi?1. Start Enhanced Diagnostics System program(WP 0086 00j) and select the correspondingsymptom.2. Start main engine, energize hydraulics, and setengine speed to 1800 rpm(TM 9--2350--292--10).3. Deploy boom to maximum live position.4. Hold control handle in forward position andrecord pressure at BR port of hydraulic controlvalve manifold assembly.5. Shut down hydraulics and main engine(TM 9--2350--292--10).yesnoNotify Direct SupportMaintenance.