TM 9--2350--292--20--20649 00--5AUXILIARY POWER UNIT WIRING HARNESS 3W711 REPLACEMENT (HATZ)-- CONTINUED0649 00Installation--Continued6. Install wiring harness 3W711 wire 65 (26) on starter relay terminal (27) with screw (23), new springwasher (24)and flat washer (25).7. Place a four--inch piece of insulation sleeving (48) over wiring harness 3W730 wire 135A (21) and wire 134 (20), wire N(19) and wiring harness 3W711 wire 66 (18), then install lead assemblies on starter relay terminal (22) with screw (14),two new lockwashers (15), new lockwasher (16) and nut (17).8. Apply adhesive to starter relay terminal (22) and attaching hardware.9. Slide insulation sleeving (48) over starter relay terminal (22) and attaching hardware. Shrink insulation sleeving(48) with electrical heat gun.14151815161722232726242519 202148