TM 9--2350--292--20--20660 00--2AUXILIARY POWER UNIT THERMOSTATIC SWITCH REPLACEMENT (HATZ)-- CONTINUED0660 00Installation1. Install two thermostatic switches (5 and 10) in oil filter assembly (11).2. Install wiring harness 3W711 leads 233A (8) and GND E11 (9) on thermostatic switch S1 (10) with two screws (6)and two lockwashers (7).3. Install wiring harness 3W711 leads 233B (3) and GND E9 (4) on thermostatic switch S2 (5) with two screws (1)and two lockwashers (2).4. Apply adhesive to all exposed electrical terminals.10976678111122435NOTEFOLLOW--ON MAINTENANCE:Install APU cover (WP 0413 00)Connect battery power (WP 0256 00)END OF TASK