TM 9--2350--292--20--2
0690 00--2
MAIN HYDRAULIC PUMPS SWITCH, TRANSDUCERS AND ASSOCIATED
PARTS REPLACEMENT -- CONTINUED
0690 00
Removal--Continued
WARNING
WARNING
Hydraulic system pressure is rated 4450 psi. Do not
torque hydraulic fittings or perform removal procedures
when hydraulic system is pressurized. Discharging sys-
tem pressure before performing any maintenance proce-
dures will avoid injury to personnel.
Eye protection will be worn when performing mainte-
nance procedures on all hydraulic components to avoid
injury to personnel.
CAUTION
Cap all hydraulic lines and plug all hydraulic ports to pre-
vent contamination. Failure may result in damage to hy-
draulic system.
All serviceable components must be placed in plastic
bags to prevent contamination of hydraulic system during
installation.
NOTE
All hydraulic lines and components must be tagged be-
fore removal for identification during installation.
Place rags under hydraulic connections to catch any hy-
draulic fluid that spills during maintenance. Dispose of
fluid soaked rags in accordance with standard operating
procedure.