TM 9--2350--292--20--2
0587 00--15
AUXILIARY POWER UNIT ASSEMBLY REPLACEMENT (HATZ) -- CONTINUED
0587 00
Installation--Continued
NOTE
Perform the following steps to connect generator air duct
hose on APU assembly.
15. Install clamp (25) over air duct hose (26). Install metal grille (27) into air duct hose (26). Position clamp (25) to
hold metal grille (27) and tighten clamp (25).
16. Install two screws (21), two new lockwashers (22), two flat washers (23) and cover (24).
25
27
23
22
21
24
26