TM 9--2350--292--20--2
0587 00--18
AUXILIARY
POWER UNIT
ASSEMBLY REPLACEMENT (HATZ) -- CONTINUED
0587 00
Installation--Continued
21. Connect GND wire (7) of APU wiring harness to single wire junction (8) of vehicle wiring harness.
22. Connect APU wiring harness 3W711 connector P1 (5) to vehicle wiring harness connector (6).
23. Connect APU wiring harness 3W704 connector P1 (3) to vehicle wiring harness connector (4).
24. Connect APU wiring harness 3W730 connector P3 (1) to door fan connector (2).
5
6
3
4
7
8
1
2
NOTE
FOLLOW--ON MAINTENANCE:
Install personnel heater
exhaust
hose
(WP 0532 00)
Close APU access door (TM 9--2350--292--10)
Close engine deck access door
(TM 9--2350--292--10)
Connect battery power (WP 0256 00)
Lower boom (TM 9--2350--292--10)
END OF TASK