TM 1-1680-320-13&P
0014 00
HIGH PERFORMANCE RESCUE HOIST ASSEMBLY
CLEANING UNDER USUAL CONDITIONS
INITIAL SETUP
Personnel Required: 2
References:
UH-1: 15N, Helicopter Repairer
AVUM/AVIM Manual for General Aircraft
UH-60: 15T, Helicopter Repairer
Maintenance TM 1-1500-204-23 series
Hoist Certified: 91W, Flight Medic
Avionic Cleaning and Corrosion
Prevention/Control TM 1-1500-344-23 series
Parts/Materials:
Lubricating Oil
Tools and Special Tools:
Air Source, 35 psi (241.3 kPa)
SALT WATER
WARNINGS
Perform all cleaning in a well lit, clean, and properly ventilated room.
To avoid injury to personnel from broken wire strands, leather gloves must be
worn at all times when handling cable assembly.
CAUTIONS
Ensure electrical connectors and control panel are covered to prevent salt
water from intruding.
Do not clean parts with chlorinated solvents, such as freon,
perchloroethylene, trichloroethane, carbon tetrachloride, etc. Do not use any
type of silicone grease on any components.
1. Immediately after salt water operations perform cleaning procedures, Cleaning Under Usual Conditions, to
prevent damage to cable and hoist assembly.