TM 1-1680-320-13&P
0023 00
HIGH PERFORMANCE RESCUE HOIST ASSEMBLY
WINCH ASSEMBLY - REPAIR
INITIAL SETUP
Personnel Required: 1
References:
UH-1: 15N, Helicopter Repairer
AVUM/AVIM Manual for General Aircraft
UH-60: 15T, Helicopter Repairer
Maintenance TM 1-1500-204-23 series
Hoist Certified: 91W, Flight Medic
Cleaning and Corrosion Control Manual
Electrical: 15F, Aircraft Electrical Repairer
TM 1-1500-344-23 series
Parts/Materials:
WD-40 or equivalent
Tools and Special Tools:
Tool Kit, Aircraft Mechanic
Shop Set, Intermediate Maintenance
Tool Kit, Electrical Repairer
Air Source, 35 psi (241.3 kPa)
CLEANING
WARNINGS
Perform all cleaning in a well lit, clean, and properly ventilated room.
Use approved personnel protective equipment (goggles/face shield) when
using compressed air. Air pressure is restricted to a maximum of 35 psi. Do
not direct air stream towards self or other personnel as injury may occur.
Cleaning Solvent is combustible and toxic to eyes, skin, and respiratory tract.
Wear protective gloves and goggles/face shield. Avoid repeated or prolonged
contact. Use only in well ventilated areas (or use approved respirator as
determined by local safety/industrial hygiene personnel). Keep away from
open flames or other sources of ignition.
Trichloroethane is toxic to eyes, skin, and respirator tract. Skin and eye
protection required. Avoid repeated or prolonged contact. Good general
ventilation is normally adequate.
CAUTIONS
Do not immerse electrical components in cleaning solvent. Wipe clean with a
cloth dampened in soap and water solution.
If parts are not to be inspected immediately after cleaning, apply WD-40 to
prevent rust spots.
1. Clean electrical connector contact pins with cloth soaked in trichloroethane.
2. Wash remaining components in cleaning solvent, rinse thoroughly, and dry with compressed air.