TM 1-1680-320-13&P
0036 00
HIGH PERFORMANCE RESCUE HOIST ASSEMBLY
ELECTRICAL CABLES AND CONNECTORS - CLEAN
INITIAL SETUP
Personnel Required: 1
References:
UH-1: 15N, Helicopter Repairer
AVUM/AVIM Manual for General Aircraft
UH-60: 15T, Helicopter Repairer
Maintenance TM 1-1500-204-23 series
Hoist Certified: 91W, Flight Medic
Aircraft Electrical and Electronic Manual
Electrical: 15F, Aircraft Electrical Repairer
TM 1-1500-323-24
Parts/Materials:
Tools and Special Tools:
N/A
WARNINGS
Perform all cleaning in a well lit, clean, and properly ventilated room.
Trichloroethane is toxic to eyes, skin, and respirator tract. Skin and eye
protection required. Avoid repeated or prolonged contact. Good general
ventilation is normally adequate.
CAUTION
Do not immerse electrical components in cleaning solvent. Wipe with a clean
cloth dampened in soap and water solution.
1. Clean rescue hoist assembly wiring harness and control panel assembly with low-lint cloth, moistened with
trichloroethane.
2. Clean electrical contact pins with cloth soaked with trichloroethane.