GOV. CONTROLS & CARB. LINKAGEModels 190000, 200000, 230000, 240000, 300000, 320000REMOTE GOVERNOR CONTROLAttach remote control casing and wire as shown inFigure 93 or Figure 94. Do not change the position ofthe small elastic stop nuts. They provide for a governedidle speed and protection against overspeeding.THUMB NUT ADJUSTMENTRemove thumb nut and upper elastic stop nut. Replacethumb nut and adjust to desired operating speed. SeeFigure 95. Do not change the position of the lowerelastic stop nut. It provides protection againstoverspeeding .GOVERNED IDLEAll engines in Model Series 243400, 300400, 320400and some Model Series 23D and 233400 engines usetwo governor springs as shown in Figures 96 and 97.The shorter spring keeps the engine on governor, evenat idle speed. If moderate loads are applied at idle, theengine will not stall.TO ADJUST FOR GOVERNED IDLEFirst make final carburetor mixture adjustments. Thenplace remote control in idle position. Hold throttle shaftin closed position and adjust idle screw to 1000 R.P.M.Release the throttle. With remote control in idle position,adjust upper elastic stop nut to 1200 R.P.M. See Fig. 97.MODELS 190000, 200000, 230000, 240000, 300000, 320000Fig. 93Fig. 94Fig. 95Fig. 96Fig. 9712