TM 9-2350-238-10
Table 3-1. TROUBLESHOOTINGCONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
CAB, BOOM, AND WINCHESCONTINUED
Step 2. Check to see if sensing switches are out of adjustment.
Adjust level wind. Refer to page 3-51. If trouble continues, notify
unit maintenance personnel.
CAB ELECTRICAL SYSTEM
37. ONE OR BOTH FLOODLIGHTS DO NOT OPERATE.
Step 1.
Check to see if floodlight switch in cab is in OFF position.
Set switch to ON position.
Step 2. Check to see if switch at floodlight is in OFF position.
Set switch to ON position. If floodlight still will not light, lamp may
be burned out. Notify unit maintenance personnel.
38. FLASHER LIGHT DOES NOT OPERATE.
Step 1.
Check to see if flasher light switch in cab is in OFF position.
Set flasher light switch to ON position.
Step 2. Check to see if switch at flasher light is in OFF position.
Set switch to ON position. If flasher light still will not light, lamp
may be burned out. Notify unit maintenance personnel.
39. FLASHER INDICATOR LAMP DOES NOT LIGHT.
Step 1.
Check to see if flasher light switch in cab is in OFF position.
Set flasher light switch to ON position.
Step 2. Check to see if flasher lamp is operating.
If flasher lamp is operating, notify unit maintenance personnel to
replace indicator lamp light bulb.
3-27