TM 9-2350-238-34-2
2-44. MAINTENANCE OF SOLENOID VALVE (CONT).
LOW PRESSURE SETTING CHECK (CONT)
4
5
6
7
8
Install 500 psi (3448 kPa) oil pressure
tester in test port (3) of solenoid valve
(2).
Set LEVEL WIND switch (4) to OFF.
Hydraulic system is under high pres-
sure. Follow hydraulic system safety
procedures to prevent injury (TM
9-2350-238-20-2). Wipe up spilled
hydraulic fluid.
Turn on hydraulic system. Refer to TM
9-2350-238-10.
Read oil pressure tester. If pressure is
less than 135 psi (931 kPa) or more than
500 psi (3448 kPa), replace solenoid
valve (2). Refer to page 2-192.
Turn off hydraulic system. Refer to TM
9-2350-238-10.
9 Disconnect oil pressure tester from
solenoid valve (2).
OIL
PRESSURE
TESTER
OIL
PRESSURE
TESTER
2-216