TM 9-2350-238-34-22-24. MAINTENANCE OF WINCH CONTROL CYLINDER (CONT).REASSEMBLY (CONT)6 Install plate positioner spacer (13),setscrew (14), head breather machinethread plug (15), and internal retainingring (16) on cylinder (5).t e s t2 Connect hydraulic line to inlet port ofcylinder.3 Apply 3000 psi (20,685 kPa) pressure andHydraulic system is under highhold for 5 minutes. If leakage occurs, re-pressure. Follow hydraulic systemplace winch control cylinder.safety procedures to prevent injury(TM 9-2350-238-20-2), Wipe up4 Release pressure. Remove hydraulic linespilled hydraulic fluid.and cover inlet port.1 Refer to TM 9-4940-468-14 for test setupand testing procedures.2-68