TM 9-2350-256-20-1
0042 00
CORRECTIVE ACTION Continued
8.
Close air inlet doors (TM 9-2350-256-10). Raise boom (TM 9-2350-256-10). Open air inlet doors.
Place red lead of multimeter on wire 49 at positive terminal and black lead to ground. Turn MASTER
switch on and check for voltage. Turn MASTER switch OFF. If voltage is present, go to step 9. If
voltage is not present, replace/repair wire 49 of batteries to master relay, voltage regulators, slave
receptacle, and engine disconnect wiring harness (see WP 0190 00 for dual voltage; 0191 00 for single
voltage).
9.
Place red lead of multimeter on wire 50 at negative terminal and black lead to ground. Check for
continuity. If continuity is present, replace rear slave receptacle (see WP 0226 00). If continuity is not
present, replace/repair bulkhead rear slave receptacle wiring harness (see WP 0226 00).
END OF WORK PACKAGE
0042 00-7/8 blank