TM 9-2350-256-20-1
0043 00
CORRECTIVE ACTION Continued
4.
Reconnect switch panel to neutral safety to bulkhead wiring harness to main switch panel. Disconnect
wire 14 at Y-connector on switch panel side. Place red lead of multimeter in wire 14 and black lead to
ground. Turn MASTER switch on, push START switch, and check for voltage. Turn MASTER switch
OFF. If voltage is present, go to step 5. If voltage is not present, replace/repair wire 14 of switch panel
to neutral safety to bulkhead wiring harness (see WP 0203 00).
5.
Reconnect wire 14 to Y-connector on switch panel side. Disconnect wire 14 from bulkhead side of
neutral safety switch. Place red lead of multimeter in male connector of neutral safety switch and black
lead to ground. Turn MASTER switch on, push START switch and check for voltage. Turn MASTER
switch OFF. If voltage is present, go to step 6. If voltage is not present, ensure bolt (1) is making contact
with neutral safety switch. If no contact is present adjust neutral safety switch (see WP 0163 00). If
contact is present replace neutral safety switch (see WP 0163 00).
0043 00-5