13. Disconnect switch panel to gage panel and miscellaneous switches wiring harness from main switch
panel. Place red lead of multimeter on pin M of wire 10 and black lead to ground. Turn MASTER
switch on and check for voltage. Turn MASTER switch OFF. If voltage is present, repair/replace wire
10 of circuit breaker to main switch panel wiring harness. If voltage is not present, troubleshoot battery
power circuit.
14. Check for voltage at wire 82 of starter solenoid. If voltage is present, replace starter motor (see WP
0152 00). If voltage is not present replace starter module (see WP 0189 00).
END OF WORK PACKAGE