TM 9-2350-256-20-1
0044 00
CORRECTIVE ACTION Continued
16. Place a jumper wire from bracket to hull to ground the panel. Reconnect switch panel and miscellaneous
switches wiring harness to main switch panel. Disconnect wire 14 from START switch side of 20 A
circuit breaker. Place red lead of multimeter on terminal of 20 A circuit breaker and black lead to
ground. Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is
present, go to step 18. If voltage is not present, go to step 17.
17. Reconnect wire 14 to START switch side of 20 A circuit breaker. Disconnect wire 10 from 20 A circuit
breaker. Place red lead of multimeter in wire 10 and black lead to ground. Turn MASTER switch on
and check for voltage. Turn MASTER switch OFF. If voltage is present, replace circuit breaker (see
WP 0159 00). If voltage is not present, repair/replace wire 10 of main lighting and B.O. selector switch
wiring harness (see WP 0218 00).
0044 00-11