4.
Reconnect switch panel to neutral safety to bulkhead wiring harness to main switch panel. Install
main switch panel (5), flat washer (4), ground lead (3), three lockwashers (2), and three screws (1) to
mounting brackets. Open air inlet doors (TM 9-2350-256-10). Disconnect bulkhead to engine wiring
harness and starter relay wiring harness from bulkhead. Place red lead of multimeter on pin D of wire
54 and black lead to ground. Turn MASTER and ENGINE FUEL SHUTOFF switches on, and check
for voltage. Turn MASTER and ENGINE FUEL SHUTOFF switches OFF. If voltage is present, go
to step 5. If voltage is not present, repair/replace wire 54 of switch panel to neutral safety to bulkhead
wiring harness (see WP 0203 00).