TM 9-2350-256-20-1
0044 00
CORRECTIVE ACTION Continued
18. Reconnect wire 14 to 20 A circuit breaker. Disconnect connector from START switch. Place red lead
of multimeter in wire 14 from circuit breaker and black lead to ground. Turn MASTER switch on and
check for voltage. Turn MASTER switch OFF. If voltage is present, go to step 19. If voltage is not
present, repair/replace wire 14 of main lighting and B.O. selector switch wiring harness (see WP 0219
00).
19. Place jumper in wire 14 from circuit breaker to START switch input terminal. Place red lead of
multimeter on START switch output terminal and black lead to ground. Turn MASTER switch on,
push START switch, and check for voltage. Turn MASTER and START switches OFF. If voltage is
present, repair/replace wire 14 of starter switch wiring harness (see WP 0206 00). If voltage is not
present, replace START switch (see WP 0159 00).
END OF WORK PACKAGE
0044 00-12