TM 9-2350-256-20-1
0064 00
CORRECTIVE ACTION Continued
6.
Reconnect switch panel to gage panel and miscellaneous switches wiring harness to switch panel.
Disconnect wire 27 from Y-connector. Place red multimeter lead on wire 27 and black lead to ground.
Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is present, go to
step 7. If voltage is not present, repair/replace wire 27 of switch panel to gage panel and miscellaneous
switches wiring harness (see WP 0204 00 for dual voltage; 0205 00 for single voltage).
0064 00-6