TM 9-2350-256-20-1
0065 00
CORRECTIVE ACTION Continued
5.
Place jumper wire from socket N to pin N. Place red lead of multimeter in socket K of switch panel and
black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If
voltage is present, go to step 6. If voltage is not present, go to step 8.
6.
Reconnect switch panel to gage panel and miscellaneous switches wiring harness to main switch
panel. Disconnect wire 27 from Y-connector. Place red multimeter lead on wire 27 and black lead to
ground. Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is
present, go to step 7. If voltage is not present, repair/replace wire 27 of switch panel to gage panel and
miscellaneous switches wiring harness (see WP 0204 00 for dual voltage; 0205 00 for single voltage).
0065 00-6