TM 9-2350-256-20-1
0065 00
CORRECTIVE ACTION Continued
8.
Reconnect switch panel to gage panel and miscellaneous switches wiring harness to switch panel.
Disconnect wire 10 from 15 A circuit breaker. Place red lead of multimeter on wire 10 and black lead
to ground. Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is
present, go to step 9. If voltage is not present, repair/replace wire 10 of switch panel to gage panel and
miscellaneous switches wiring harness (see WP 0204 00 for dual voltage; 0205 00 for single voltage).
9.
Reconnect wire 10 to 15 A circuit breaker. Disconnect wire 25-27 from 15 A circuit breaker. Place
red lead of multimeter on terminal of circuit breaker and black lead to ground. Turn MASTER switch
on and check for voltage. Turn MASTER switch OFF. If voltage is not present, replace 15 A circuit
breaker (see WP 0159 00). If voltage is present, go to step 10.
0065 00-8