TM 9-2350-256-20-1
0080 00
CORRECTIVE ACTION Continued
9.
Install main switch panel (11), flat washer (10), ground lead (9), three lockwashers (8), and three screws
(7). Reconnect switch panel to gage panel and miscellaneous switches wiring harness to main switch
panel. Disconnect wire 75/16 at stoplight switch. Place red lead of multimeter in wire 75/16 and black
lead to ground. Turn MASTER switch on, press SER DRIVE key and ENTER key of main lighting
switch, and check for voltage. Turn MASTER and main lighting switches OFF. If voltage is present,
go to step 10. If voltage is not present, repair/replace wire 75/16 of switch panel to gage panel and
miscellaneous switches wiring harness (see WP 0204 00 for dual voltage; 0205 00 for single voltage).
10. Reconnect wire 75/16 to stoplight switch. Disconnect wire 75 from stoplight switch. Place red lead
of multimeter on wire 75 of stoplight switch and black lead to ground. Turn MASTER switch on,
UNLOCK and place main lighting switch in SER. DRIVE position, depress stoplight switch, and
check for voltage. Turn MASTER, main lighting, and stoplight switches OFF. If voltage is present,
repair/replace wire 75 of switch panel to gage panel and miscellaneous switches wiring harness (see
WP 0204 00 for dual voltage; 0205 00 for single voltage). If voltage is not present, replace stoplight
switch (see WP 0172 00).
0080 00-8