4.
Remove three screws (7), three lockwashers (8), ground wire (9), flat washer (10), and release main
switch panel (11) from mounting brackets. Disconnect switch panel to gage panel and miscellaneous
switches wiring harness from main switch panel. Place red lead of multimeter on pin N of wire 10 and
black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If
voltage is present, go to step 5. If voltage is not present, go to step 11.
5.
Place red lead of multimeter on pin D of wire 75/16 and black lead on pin L of wire 75. Check for
continuity. If continuity is present, go to step 6. If continuity is not present, go to step 9.