TM 9-2350-256-20-1
0116 00
Testing
1.
Disconnect fuel tank supply hose quick disconnect (see WP 0123 00). Open coupling valve to collect fuel in suitable,
5-gallon (19-liter) container.
2.
Turn MASTER switch and in-tank fuel pump switch to ON position (refer to TM 9-2350-256-10).
3.
Time fuel flow into measured container.
4.
Flow rate of 3 gallons per minute (11 liters per minute) is satisfactory. Replace electric fuel pump if rate of flow is less than
3 gallons per minute (11 liters per minute).
NOTE
Follow-on maintenance: Install intermediate rear left center floor plate (see WP 0302 00).
END OF WORK PACKAGE
0116 00-6