TM 9-2350-256-20-1
0130 00
5.
Disconnect fuel/water separator filter drain hose (8) from solenoid valve (9).
6.
Disconnect wiring harness connector (1) from solenoid valve (9).
7.
Disconnect solenoid valve drain tube (10) from solenoid valve (9).
8.
Remove two assembled washer screws (11) and remove solenoid valve (9) from mounting bracket (12).
9.
Remove mounting bracket (12) by removing four screws (13), four lockwashers (14), ground (15), and clamp (16).
10. Remove nipple (17) from solenoid valve (9) IN opening and elbow (18) from solenoid valve OUT opening.
Installation
1.
Install mounting bracket (12), ground (15), and clamp (16) with four screws (13) and four lockwashers (14).
2.
Install control module (3) and clamp (7) with four screws (5) and four flat washers (6).
3.
4.
Connect two wiring harness connectors (1 and 2) to control module (3).
5.
Install nipple (17) in solenoid valve (9) IN opening and elbow (18) in solenoid valve OUT opening.
6.
Install solenoid valve (9) on mounting bracket (12) and secure with two assembled washer screws (11).
0130 00-2