TM 9-2350-256-20-1
0131 00
Installation
1.
Install manifold heater fuel supply solenoid valve (6) to bracket (16) with two screws (17) and two lockwashers (18).
2.
Install manifold heater fuel supply solenoid valve (6) to fuel filter (4) with nipple (15).
3.
Install nipple (13) to fuel filter (4), then install fuel outlet tee (2) and elbow (14) to manifold heater fuel supply solenoid
valve (6).
4.
Install four slotted-head screws (10), four lockwashers (11), and two flat washers (12) to bracket (7).
5.
Install manifold heater fuel supply solenoid valve (6) with fuel filter (4) and bracket (7) as an assembly with two nuts (8)
and two flat washers (9).
6.
Connect electrical harness plug (5) and fuel filter inlet tube (3) to fuel filter (4).
7.
Connect two manifold heater fuel tubes (1) to fuel outlet tee (2).
NOTE
Follow-on maintenance: Turn MASTER switch to ON position; Install air inlet grille (see WP 0342 00).
END OF WORK PACKAGE