TM 9-2350-256-20-1
0133 00
Installation
NOTE
If fuel return check valve (13) is removed, it must be installed with arrow pointing down.
1.
Install outlet elbow (12), fuel return check valve (13), and elbow (14) on solenoid valve (4).
2.
Install tee (11), elbow (10), and fuel solenoid inlet coupling (9) on solenoid valve (4).
3.
Install mounting bracket (5) with three assembled washer bolts (8).
4.
Install solenoid valve (4) with related fittings on mounting bracket (5) with two flat washers (7) and two assembled washer
bolts (6).
5.
Connect fuel solenoid outlet tube (2) and two fuel solenoid inlet tubes (3).
6.
Connect electrical wiring harness connector (1).
NOTE
Follow-on maintenance: Turn MASTER switch to ON position; Install engine deck (see WP 0336 00).
END OF WORK PACKAGE
0133 00-3/4 blank