TM 9-2350-256-20-2
0235 00
6.
Disconnect connector (4) from bilge pump (12).
Disassembly
1.
Disassemble wiring harness (see WP 0255 00 thru 0264 00, as appropriate).
Assembly
1.
Assemble wiring harness (see WP 0255 00 thru 0264 00, as appropriate).
Installation
NOTE
Perform step 1 only if deep water fording kit is installed.
1.
Connect connector (4) to bilge pump (11).
2.
Install strap (5).
3.
Install cap assembly (10) on connector (4).
4.
Connect lead (3) to circuit breaker (7) using screw (8) and lockwasher (9).
5.
Connect connector (2) to bilge pump relay (6).
6.
Connect connector (1) to electrical accessories panel wiring harness (5).
NOTE
Follow-on maintenance: Close stowage basket forward intermediate left floor plate (see WP 0306 00).
END OF WORK PACKAGE