CHAPTER 10: MAINTENANCE OF PERSONNEL HEATER AND CONNECTINGTM 9-2350-256-20COMPONENTS, AND FIXED FIRE EXTINGUISHER SYSTEM10-6 REPLACE/SERVICE FIRE EXTINGUISHER SYSTEM CONTROLS AND LINKAGESTHIS TASK COVERSa. Removalb. Installationc. AdjustmentINITIAL SET-UPTools:Parts:Equipment Condition:Tool kit, generalGasket (Appendix G, item 63)Heater control box removedmechanic's (Appendix C,Lockwashers (2) (Appendix G, item 105)(see paragraph 6-12)item 53)Lockwashers (2) (Appendix G, item 130)Riveter, blind (AppendixLockwashers (2) (Appendix G, item 132)C, item 42)Lockwashers (2) (Appendix G, item 137)Rivet (Appendix G, item 236)Seals (4) (Appendix G, item 266)a. REMOVAL1 Remove two seals (1), two manual control levers (2), and two fastener assemblies (3) from two cables (4).2 Remove cover (5) by removing three screws (6).3 Remove pull-release mechanism (7) and gasket (8) by loosening two nuts (9) and two lockwashers (10) and pullingcable through pull-release mechanism.4 Pull two cables (4) through hull and remove two lockwashers (10) and two nuts (9).5 Remove two adapters (11), two swivel connectors (12), and two conduits (13) from two cables (4).10-16