SECTION II: FIXED FIRE EXTINGUISHER SYSTEM
TM 9-2350-256-20
6 Remove quick-release pin (14) from shield (15) .
NOTE
Perform step 7 only if quick-release pin
chain (16) is damaged and must be
replaced.
7 Remove quick-release pin chain (16) from shield
(15) by removing rivet (17).
8 Remove screw (18), two nuts (19 and 20), and stop
(21) from shield (15).
9 Remove shield (15) from bracket (22) by removing
two nuts (23), two lockwashers (24), and two
screws (25).
10 Remove interlock switch assembly (26) from
bracket (22) by disconnecting two leads (27) and
removing locknut (28).
11 Remove two seals (29) from two manual control
levers (30).
12 Remove two manual control levers (30) by
unscrewing two conduit nuts (31) and removing
two fastener assemblies (32), two reducers (33), and
two nuts (34) from two cables (35).
13 Pull two cables (35) through bracket (22).
14 Remove bracket (22) by removing two screws (36)
and two lockwashers (37).
10-17