CHAPTER 10: MAINTENANCE OF PERSONNEL HEATER AND CONNECTING
TM 9-2350-256-20
COMPONENTS, AND FIXED FIRE EXTINGUISHER SYSTEM
10-6 REPLACE/SERVICE FIRE EXTINGUISHER SYSTEM CONTROLS AND LINKAGES-Continued
15 Remove two conduits (38) from two cables (35) .
16 Remove two screws (39) and slide two adjustable
elbows (40) from two cables (35).
17 Remove two adjustable elbow brackets (41) by
removing two screws (42).
18 Remove two conduits (43) and two swivel
connectors (44) from two cables (35).
19 Remove two cylinder control valves (45) (see
paragraph 10-5) from two cables (35).
20 Remove two conduits (46) and two swivel
connectors (47) from two cables (35).
21 Remove two dual-pull mechanisms (48) with
cables (4 and 35) by removing two screws (49), two
lockwashers (50), and two clips (51).
22 Open two dual-pull mechanisms (48) and remove
four cables (4 and 35) as follows: grasp 3/16 in. (5
mm) of each end of cable damp (52) with pliers.
Rotate ends of clamp simultaneously until cable
clamp has been untwisted and cables are released.
b. INSTALLATION
1 Install two fastener assemblies (3) and two manual control levers (2) on two cables (4).
2 Install new gasket (8) and pull-release mechanism (7) with two new lockwashers (10) and two nuts (9).
3 Install two cables (4) through pull-release mechanism (7).
10-18