CHAPTER 10: MAINTENANCE OF PERSONNEL HEATER AND CONNECTING TM 9-2350-256-20COMPONENTS, AND FIXED FIRE EXTINGUISHER SYSTEM10-6 REPLACE/SERVICE FIRE EXTINGUISHER SYSTEM CONTROLS AND LINKAGES-Continued15 Remove two conduits (38) from two cables (35) .16 Remove two screws (39) and slide two adjustableelbows (40) from two cables (35).17 Remove two adjustable elbow brackets (41) byremoving two screws (42).18 Remove two conduits (43) and two swivelconnectors (44) from two cables (35).19 Remove two cylinder control valves (45) (seeparagraph 10-5) from two cables (35).20 Remove two conduits (46) and two swivelconnectors (47) from two cables (35).21 Remove two dual-pull mechanisms (48) withcables (4 and 35) by removing two screws (49), twolockwashers (50), and two clips (51).22 Open two dual-pull mechanisms (48) and removefour cables (4 and 35) as follows: grasp 3/16 in. (5mm) of each end of cable damp (52) with pliers.Rotate ends of clamp simultaneously until cableclamp has been untwisted and cables are released.b. INSTALLATION1 Install two fastener assemblies (3) and two manual control levers (2) on two cables (4).2 Install new gasket (8) and pull-release mechanism (7) with two new lockwashers (10) and two nuts (9).3 Install two cables (4) through pull-release mechanism (7).10-18