SECTION V: TROUBLESHOOTING
TM 9-2350-256-20
WARNING
Remove all jewelry such as rings, dog tags,
bracelets, etc. If jewelry contacts a metal
surface a direct short may result in instant
heating of tools, damage to equipment,
and injury or death to personnel.
A
Open air inlet doors (TM 9-2350-256-10). Place red
multimeter lead on positive post and black lead to
ground. Check for voltage. If voltage is below 18 Vdc,
clean, tighten, repair, or replace necessary cables.
Crank engine and check voltage. If voltage is still
below 18 Vdc, go to step B.
B
Place red multimeter lead on positive post and black
lead on negative post of battery 1. Voltage reading
should not be below 9 Vdc. Repeat on batteries 2, 3,
4, 5, and 6. If any battery voltage is below 9 Vdc
replace battery (see paragraph 6-4).
2-59