CHAPTER 2: VEHICLE MAINTENANCE INSTRUCTIONSTM 9-2350-256-202-19 ELECTRICAL TROUBLESHOOTING-ContinuedVENTILATION BLOWER SYSTEM-ContinuedWARNINGRemove all jewelry such as rings, dog tags,bracelets, etc. If jewelry contacts a metalsurface a direct short may result in instantheating of tools, damage to equipment, andinjury or death to personnel.HReconnect electrical accessories panel wiring harness toelectrical accessories panel. Open air inlet doors (TM 9-2350-256-10). Disconnect wire 48 pin A from bulkheadto master relay wiring harness. Place red multimeterlead in socket and black lead to ground. Turn MASTERswitch on and check for voltage. Turn MASTER switchOFF. If voltage is present, repair/replace switch panel,radio, and bilge pump to bulkhead wiring harness (seeparagraph 6-53). If voltage is not present, troubleshootmaster relay circuit (see paragraph 2-19, master relayfails to operate).2-332
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business