SECTION V: TROUBLESHOOTING
TM 9-2350-256-20
WARNING
Remove all jewelry such as rings, dog tags,
bracelets, etc. If jewelry contacts a metal
surface a direct short may result in instant
heating of tools, damage to equipment, and
injury or death to personnel.
A
Disconnect electrical accessories panel wiring harness
from electrical accessories panel. Place red lead of
multimeter in socket A of wire 38/59 and black lead to
ground. Turn MASTER switch on and check for voltage.
Turn MASTER switch OFF. If voltage is present, go to
step B. If voltage is not present, go to step H.
B
Place a jumper wire from socket A to pin A. Place red
lead of multimeter on pin B of wire 59 and black lead to
ground. Turn MASTER and VENT BLOWER switches
ON and check for voltage. Turn MASTER and VENT
BLOWER switches OFF. If voltage is present, go to
step G. If voltage is not present, go to step C.
2-329