SECTION 111: AIR INTAKE SYSTEM
TM 9-2350-256-20
4
Install flange (24) and collar (23) with six flat
washers (22) and six screws (21).
5
Install air cleaner housing (19), six spacer plates
(20), eight flat washers (18), four new lockwashers
(
17), and four screws (16).
6
Install three retaining bolts (15) with three flat
washers (14), three new lockwashers (13), and three
nuts (12).
7
Install clamp (10) to air inlet opening (11).
8
Install bracket (9) with three flat washers (8), three
new lockwashers (7), and three screws (6).
9
Install filter element (5) with washer (4) and wingbolt (3).
10 Install air cleaner cover assembly (2) by tightening four wingnuts (1).
4-53