CHAPTER 6: MAINTENANCE OF ELECTRICAL SYSTEMS AND CIRCUITSTM 9-2350-256-206-54 REPLACE/REPAIR SWITCH PANEL TO NEUTRAL SAFETY TO BULKHEADWIRING HARNESS (11671420)--ContinuedWARNINGBe certain MASTER switch is OFF when working on electrical systems to avoid electrical shock and bums.Connector No.Electrical Lead To:Wire No.1Main switch panel14, 76, 542Electrical accessories panel wiring harness13Electrical accessories panel wiring harness14Neutral safety switch145Neutral safety switch146Manifold preheat switch assembly4867Circuit breaker4868Manifold preheat switch assembly4869Electrical fuel pumpGND, 7610GroundGND11Bulkhead disconnect14, 486, 54, 1,61A, 1, 6112APU control box to foot dimmer switch and bulkhead wiring61Aharness13APU control box to foot dimmer switch and bulkhead wiring61harness14Fire extinguisher engine shutoff switch 54A6—120