SECTION V: VEHICLE WIRINGTM 9-2350-256-205 Connect connector (3) to switch panel to gage panel and miscellaneous switches wiring harness (passive nightviewer) (dual voltage) (15).6 Install 19 clamps (12) using new lockwasher (14) and screw (13) for each.7 Connect lead (2) using new lockwasher (11) and screw (10).8 Connect connector (1) to APU control box (9).NOTEFollow-on maintenance:Install air cleaner (see paragraph 4-24)6-80 APU CONTROL BOX TO FOOT DIMMER SWITCH AND BULKHEAD WIRINGHARNESS (SINGLE VOLTAGE) (11671799)THIS TASK COVERSa. Removalb. Disassemblyc. Assemblyd. InstallationINITIAL SET-UPTools:Parts-Continued:Tool kit, general mechanic's (Appendix C, item 53)Lockwashers (19) (Appendix G, item 118)Parts:Equipment Condition:·Gasket (Appendix G, item 80)Air cleaner removed (see paragraph 4-24)·Lockwashers (4) (Appendix G, item 104)WARNINGBe certain MASTER switch is OFF when working on electrical systems to avoid electrical shock andburns.6-215