CHAPTER 6: MAINTENANCE OF ELECTRICAL SYSTEMS AND CIRCUITSTM 9-2350-256-206-78 REPLACE/REPAIR APU WIRING HARNESS (11672417)-Continued3 Disconnect lead (3) from diode assembly (16) by removing screw (17), lockwasher (18), and nut (19).4 Disconnect lead (4) from preheat solenoid (20) by removing nut (21) and washer (22).5 Disconnect lead (5) from fuel shutoff solenoid (23) by removing nut (24) and washer (25).6 Disconnect lead (6) from preheat solenoid (20) by removing nut (26) and four lockwashers (27).7 Disconnect lead (7) from preheat solenoid (20) by removing nut (29) and lockwasher (30).8 Disconnect lead (8) from APU generator (31) byremoving nut (32).9 Disconnect two leads (10 and 11) from APUgenerator (31) by removing two nuts (34).10 Disconnect lead (13) from APU generator (31) byremoving nut (35) and three lockwashers (36).6-210