SECTION VIl: TERMINAL CONNECTOR PROCEDURESTM 9-2350-256-20b. ASSEMBLY1Strip cable (3) insulation equal to depth of solder wells of socket contacts (1).2Insert cable leads (3) into solder wells of socket contacts (1) and solder (use resin core solder only) (refer to TB SIG 222).3Push insert (2) into shell (4) from rear until seated. Groove (5) in insert must be aligned with guide in shell (4) to ensure proper fit.4Push socket contacts (1) into insert (2) from rear until seated.6-111 REPAIR TYPICAL MALE-TYPE PANEL MOUNTING RECEPTACLETHIS TASK COVERSa. Disassemblyb. AssemblyINITIAL SET-UPTools:Parts:Reference:Tool kit, general mechanic'sRod (Appendix D, item 24) TB SIG 222(Appendix C, item 53)WARNINGBe certain MASTER switch is OFF when working on electrical system to avoid electrical shock and bums.NOTEIn plug and receptacle assemblies, plug all spare grommet holes with rod.a. DISASSEMBLY1Drive pin contacts (1) out through rear of insert (2) with pin extractor.2Unsolder cable leads (3) from solder wells on pin contacts (1).3Slide insert (2) out through rear of shell (4).b. ASSEMBLY1Strip cable (3) insulation equal to depth of solder wells of pin contacts (1).2Insert cable leads (3) into solder wells of pin contacts (1) and solder (use resin core solder only) (refer to TB SIG 222).3Push insert (2) into shell (4) from rear until seated. Groove (5) in insert must be aligned with guide in shell (4) to ensure proper fit.4Push pin contacts (1) into insert (2) from rear until seated.6-267