CHAPTER 9: MAINTENANCE OF HULL- AND CAB-RELATED COMPONENTSTM 9-2350-256-209-49 REPLACE APU ACCESS COVER ASSEMBLY-Continued6Install personnel heater exhaust (4) and new gasket(5) with two screws (6) and two new lockwashers (7).7Install APU cooling air shield (1) with three screws (2)and three new lockwashers (3).NOTEFollow-on maintenance:Lower boom (refer to TM 9-2350-256-10)Close right-front air inlet door (see paragraph 9-56)9-50 REPLACE APU ACCESS DOORTHIS TASK COVERSa. Removalb. InstallationINITIAL SET-UPTools:Parts:Personnel Required:Tool kit, general mechanic'sPin, cotter (Appendix G, item 212)Two(Appendix C, item 53)Pins, cotter (2) (Appendix G, item 215)a. REMOVAL1Remove APU access door (1) by removing two cotterpins (2), two straight pins (3), and two flat washers (4).2Remove door handle (5) by removing cotter pin (6),nut (7), flat washer (8), latch (9), link (10), and spring(11).b. INSTALLATION1Install door handle (5) with spring (11), link (10), latch(9), flat washer (8), nut (7), and new cotter pin (6).2Install APU access door (1) with two straight pins (3),two flat washers (4), and two new cotter pins (2).9-82