GAS-PARTICULATE FILTER UNIT TROUBLESHOOTING
0089 00
THIS WORK PACKAGE COVERS:
Lack of air at facepieces
0089 00--1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor does not operate
0089 00--1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INITIAL SETUP:
Personnel Required
Three
LACK OF AIR AT FACEPIECES
Step 1. Check for kinked, pinched, clogged or loose hose connections.
Straighten kinked or pinched hoses, unclog hoses and tighten loose connections.
Step 2. If no heated air flows, turn M3 HEATER switch ON and adjust heater.
Step 3. If problem still exists, notify unit maintenance (LACK OF AIR AT FACEPIECES).
MOTOR DOES NOT OPERATE
Step 1. Reset ON/OFF
circuit breaker
switch on control unit.
Step 2. If problem still exists, notify unit maintenance (MOTOR DOES NOT OPERATE).
END OF TASK