TM 9--2350--292--10
0091 00--2
HYDRAULICS SYSTEM TROUBLESHOOTING -- CONTINUED
0091 00
MAIN WINCH FAILS TO OPERATE OR FAILS TO DEVELOP FULL POWER
Step 1. Check oil level in hydraulic reservoir (WP 0101 00).
Fill as specified in WP 0101 00.
Step 2. Attempt to operate with PTO clutch manually engaged (WP 0045 00).
Step 3. If problem still exists, notify unit maintenance (MAIN WINCH FAILS TO OPERATE OR FAILS TO DE-
VELOP FULL POWER).
WINCH OPERATES ON AUXILIARY HYDRAULIC POWER, BUT DOES NOT OPERATE ON MAIN ENGINE HY-
DRAULIC POWER
Step 1. Check that PTO CLUTCH switch is ON.
Place PTO CLUTCH switch in ON position.
Step 2. Attempt to operate with PTO clutch manually engaged (WP 0045 00).
Step 3. If problem still exists, notify unit maintenance (PTO CLUTCH DOES NOT ENGAGE, INDICATOR IS
NOT LIT AND GOVERNOR DOES NOT OPERATE PROPERLY).
END OF TASK