TM 9--2350--292--100093 00--2MONITORING SYSTEM TROUBLESHOOTING -- CONTINUED0093 00TURBO DUST DET INDICATOR COMES ONStep 1. Check air cleaner housing for excessive contamination, and air cleaner restriction gauge indicators.Clean air filters and housings (WP 0111 00).Step 2. Turbo dust detector filter clogged light on.a. Check turbo dust detector switch on top of both turbochargers to determine which filter isclogged.Service turbo dust detector (WP 0115 00).b. Check air tubes and joints for leaks, and check clamps for tightness.c. Continue with mission and monitor indicator.d. On completion of mission, if problem still exists, notify unit maintenance [DUST DETECTORSYSTEM OPERATES IMPROPERLY (POWER PLANT WARNING LAMP AND DUST DE-TECTOR WARNING LAMP ON AND PRESSURE SWITCH PLUNGERS ARE VISIBLE)].END OF TASK